Parameters in the file para.ini: advanced configuration
SAGEM RT3000 101
Datei 8115AD002-Total.doc
Datei gespeichert 24.04.04 13:23 von EDV/ORGA
Druckzeit 24.04.04, 18:17
Status Release
Hang-up delay port
B
CHB_MTC_HOOK_TIMEOUT 0....30000 6000 = 1min
16.27 MNP Flow Control
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
The Microcom Networking Protocol MNP is used for error correction and flow control
on the link to the local connected Modem. If you want MNP active set the following
parameter as follows: MNP=YES
.
Section: MODEM
Meaning Parameter Permitted Values Factory Setting
MNP setting MNP YES,NO YES
(NO in Spain)
16.28 Maximum local modem speed
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
This parameter sets the initial baudrate for the negotiation.
Section: MODEM
Meaning Parameter Permitted Values Factory Setting
max. local speed MAX_SPEED 300, 1200, 2400,
4800, 9600, 14400
9600
16.29 Minimum local modem speed
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
This parameter sets the lowest speed accepted during baudrate negotiation.
Section: MODEM
Meaning Parameter Permitted Values Factory Setting
min. local speed MIN_SPEED 300, 1200, 2400,
4800, 9600, 14400
300