16.19 Voice signal volume on Telephone and Fax/Modem/Phone
port
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
Can be configured by DTMF (see page 80)
You can adjust the voice signal volume on the Telephone and Fax/Modem/Phone
port by modifying the following parameters
.
If you set the parameter value to “0” you
get the loudest signal.
CHx_TX_VOICE_LEVEL (Signal directed to the remote station)
CHx_RX_VOICE_LEVEL (Signal directed to your local equipment)
You can set the parameter for both ports separately.
Section: DIALING
Meaning Parameter Permitted
Values
Factory Setting
Tx Level *(-1)[dB]
on port A
CHA_TX_VOICE_LEVEL 0 down to –20 -7
Rx Level *(-1)[dB]
on port A
CHA_RX_VOICE_LEVEL 0 down to –20 -7
Tx Level *(-1)[dB]
on port B
CHB_TX_VOICE_LEVEL 0 down to –20 -7
Rx Level *(-1)[dB]
on port B
CHB_RX_VOICE_LEVEL 0 down to –20 -7
16.20 Telephone and Fax/Modem/Phone port impedance
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
You can adjust the input impedance of the Telephone and Fax/Modem/Phone port
separately. You can select 600R, 900R or a complex matching.
Section: DIALING
Parameter Permitted Values Factory Setting
Input Impedance
Port A
CHA_INPUT_IMPEDANCE REAL600,
REAL900,
COMPLEX
COMPLEX
Input Impedance
Port B
CHB_INPUT_IMPEDANCE REAL600,
REAL900,
COMPLEX
COMPLEX