Parameters in the file para.ini: advanced configuration
94 SAGEM RT3000
Datei 8115AD002-Total.doc
Datei gespeichert 24.04.04 13:23 von EDV/ORGA
Druckzeit 24.04.04, 18:17
Status Release
the amount of mark
bits
CHA_MARK_BITS 60 to 205 180
Display CLIP Port B CHB_CLIP_ENABLED YES, NO YES
define the delay
between end of first
ring and start of
CID (10ms)
CHB_RING_CLIP_DELAY 50 to 200 50
the amount of
seizure bits
CHB_SEIZURE_BITS 96 to 300 300
the amount of mark
bits
CHB_MARK_BITS 60 to 205 180
16.14 Configuration of the Flash signal
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
Can be configured by DTMF (see page 80)
Section: FLASH
Meaning Parameter Permitted
Values
Factory Setting
The minimum flash
duration. Shorter pulses
may be interpreted as
parts of pulse-dial! (10ms)
CHA_FLASH_MIN 4 - 55 7
The maximum flash
duration. Longer pulses
may be interpreted an
onhook/offhook! (10ms)
CHA_FLASH_MAX 12 - 65 50
CHx_FLASH_MIN
CHx_FLASH_MAX
No Flash
No Flash
Flash