Update the firmware
118 SAGEM RT3000
Datei 8115AD002-Total.doc
Datei gespeichert 24.04.04 13:23 von EDV/ORGA
Druckzeit 24.04.04, 18:17
Status Release
19 Update the firmware
The firmware of the RT3000 can be updated using a local connected PC (connected to
the USB or RS-232 port) or from remote.
The approach is just as if you want to configure the SAGEM RT3000 by uploading the
edited configuration file para.ini by FTP - see 15.3 Configuration by FTP (Local and
Remote), page 83.
!
The configuration data call must be initiated from a station whose telephone
number is configured in the REMOTE_ACCESS Section of the parameter file
“para.ini” (see Settings for the configuration access via SMS and FTP, page 85)
The Firmware update is done via FTP (local or remote):
Upload the file „rt3000.bin“ to the SAGEM RT3000.
Upload the file „!cmdfile“ to the SAGEM RT3000.
The file !cmdfile is a text file (plain text) containing the following command:
STORE rt3000.bin
After uploading the files the SAGEM RT3000 will reboot.
This procedure may take several minutes.
You may check the completion of the download as follows:
Via FTP you can download the file „!cmdlog“. After successful completion of
the firmware update it has the following contents:
>> STORE rt3000.bin
<< OK
OR
Enter the command ATI at the PC interface of your terminal program when
you have a data connection to the SAGEM RT3000. The new version number
should be displayed.