EasyManua.ls Logo

Sagem RT3000 - Fixed Network SMS Configuration

Sagem RT3000
121 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters in the file para.ini: advanced configuration
104 SAGEM RT3000
Datei 8115AD002-Total.doc
Datei gespeichert 24.04.04 13:23 von EDV/ORGA
Druckzeit 24.04.04, 18:17
Status Release
16.35 Fixed Network SMS
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
Section: PSTN_SMS
Meaning Parameter Permitted values Factory Setting
Telephone number
of the PSTN-SMS-
Center
(Can be configured by
DTMF (see page 80))
PSTN_SMS_CENTER Number
Max lenght 24
digits
0193010
delivery mode DELIVERY_MODE 0 only
reserved for future
0
timeout for waiting
on offhook after
ringing
RING_TIMEOUT 5 second to 10
minutes
in 10 ms steps
600
Time between
delivery tries
DELIVERY_DELAY 5 second to 10
minutes
in 10 ms steps
3000
Ignore SMSC
Header
SMSC_HEADER YES,NO NU_FALSE
Error report if sent
SMS can not be
delivered
ERROR_REPORT YES,NO YES
Protocol parameter ACK_INFO Reserved Reserved
Protocol parameter ACK_PAYLOAD Reserved Reserved
Protocol parameter ALL_SG_AT_ONCE Reserved Reserved
Telephone number
of the PSTN-SMS-
Center for RX
(Can be configured by
DTMF (see page 80))
LOCAL_NUMBER Phone number

Table of Contents

Related product manuals