Parameters in the file para.ini: advanced configuration
SAGEM RT3000 93
Datei 8115AD002-Total.doc
Datei gespeichert 24.04.04 13:23 von EDV/ORGA
Druckzeit 24.04.04, 18:17
Status Release
the tax-pulse level in
range from 0-2,5V
CHA_PULSE_LEVEL 0 to 2,5 1
the tax-pulse-
frequency, yes to use
16khz,
no for 12khz
CHA_16KHZ_BURST YES,NO YES
Enable Billing Port B CHB_BILLING_ENABLED YES,NO YES
the tax-pulse duration
in x*10ms
CHB_PULSE_DURATION 1 to 100 20
the tax-pulse delay in
x*10ms
CHB_PULSE_DELAY 1 to 60000 100
the tax-pulse level in
range from 0-2,5V
CHB_PULSE_LEVEL 0 to 2,5 1
the tax-pulse-
frequency, yes to use
16khz,
no for 12khz
CHB_16KHZ_BURST YES,NO YES
16.13 CLIP function configuration
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
Can be configured by DTMF (see page 80)
When a call comes in and it is ringing the SAGEM RT3000 can transmit the telephone
number of the calling party to the equipment connected to the Telephone port or the
Fax/Modem/Phone port. This function is called CLIP - Calling Line Identification
Presentation.
CHx_CLIP_ENABLED
= Yes Enables the transmission of the CLIP on port x (x=A,
B)
= No Disables the transmission of the CLIP on port x
(x=A, B)
Section: CLIP
This section includes the parameters for the CLIP function
Meaning Parameter Permitted
Values
Factory Setting
Display CLIP Port A CHA_CLIP_ENABLED YES, NO YES
define the delay
between end of first
ring and start of
CID (10ms)
CHA_RING_CLIP_DELAY 50 to 200 50
the amount of
seizure bits
CHA_SEIZURE_BITS 96 to 300 300