EasyManua.ls Logo

Samsung OfficeServ 100 - Figure 5.5 MDF Connections for ISDN CO Line to Card (2 BRI)

Samsung OfficeServ 100
123 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 5. Connecting Trunk Line Circuit
5-6
© SAMSUNG Electronics Co., Ltd.
25 PAIR CABLE WITH FEMALE CONNECTOR TO EXPANSION P5
25 PAIR CABLE WITH FEMALE CONNECTOR TO BASIC P2
CONNECT TO ISDN C.O CIRCUIT
SLOT NO.
PIN
NO.
FUNCTION
25,50
24,49
SxB, SxA (To N.T.)
SRB, SRA (From N.T.)
0
23,48
22,47
SxB, SxA (To N.T.)
SRB, SRA (From N.T.)
1
21,46
20,45
SxB, SxA (To N.T.)
SRB, SRA (From N.T.)
2
SLOT 4
19,44
18,43
SxB, SxA (To N.T.)
SRB, SRA (From N.T.)
3
17,42
16,41
SxB, SxA (To N.T.)
SRB, SRA (From N.T.)
0
15,40
14,39
SxB, SxA (To N.T.)
SRB, SRA (From N.T.)
2
13,38
12,37
SLOT 5
11,36
10,35
9,34
8,33
SxB, SxA (To N.T.)
SRB, SRA (From N.T.)
1
7,32
6,31
SxB, SxA (To N.T.)
SRB, SRA (From N.T.)
2
5,30
4,29
SLOT 6
3, 28
2, 27
1, 26
CO-PROVIDED
NETWORK ACCESS JACK
RJ 11C
RJ 14C
RJ 21X
Figure 5.5 MDF Connections for ISDN CO Line to Card (2BRI)
4BRI(including 2BRI) card can support both of S and T reference points defined by ITU-T.
Detailed description & MMC is referred in Programming Manual.
SLOT NO. PIN NO. FUNCTION
25, 50
24, 49
SxB, SxA(To N.T.)
SRB, SRA(From N.T.)
1
23, 48
22, 47
SxB, SxA(To N.T.)
SRB, SRA(From N.T.)
2
SLOT 1
17, 42
16, 41
SxB, SxA(To N.T.)
SRB, SRA(From N.T.)
1
15, 40
14, 39
SxB, SxA(To N.T.)
SRB, SRA(From N.T.)
2
SLOT 2
9, 34
8, 33
SxB, SxA(To N.T.)
SRB, SRA(From N.T.)
1
7, 32
6, 31
SxB, SxA(To N.T.)
SRB, SRA(From N.T.)
2
SLOT 3
1, 26

Table of Contents

Other manuals for Samsung OfficeServ 100