CHAPTER 6. Connecting Station Equipment
6-4
© SAMSUNG Electronics Co., Ltd.
25 PAIR CABLE WITH FEMALE CONNECTOR TO BASIC P1
6.2 Add-On Module
Using one pair twisted #24 AWG or #26 AWG wire, cross-connect each AOM (Add-On
Module) to the DLI port of your choice(See Figures 6.3 and 6.4).
PIN COLOR CIRCUIT FUNCTION
25
50
Grey/purple
Purple/grey
1
DLI TIP
DLI RING
24
49
Brown/purple
Purple/brown
2
DLI TIP
DLI RING
23
48
Green/purple
Purple/green
3
DLI TIP
DLI RING
22
47
Orange/purple
Purple/orange
4
DLI TIP
DLI RING
21
46
Blue/purple
Purple/blue
5
DLI TIP
DLI RING
20
45
Grey/yellow
Yell ow/ grey
6
DLI TIP
DLI RING
19
44
Brown/yellow
Yell ow/ brown
7
DLI TIP
DLI RING
18
43
Green/yellow
Yellow/green
8
DLI TIP
DLI RING
Figure 6.3 MDF Connections AOM to Basic KSU P1
CONNECT TO ANY DLI CIRCUIT ON KSU P1.
ADD-ON MODULE
ONE PAIR TWISTED
SHEATHED STATION
CABLE 24 OR 26 AWG