Information on personnel qualified to install, operate, and maintain equipment.
Instructions to read the sheet and all included materials before installation or operation.
Instruction to keep the sheet as a permanent part of the interrupter.
Information on the specific application for which the equipment is intended.
Details the standard warranty conditions and replacements for the fault interrupter.
Explains various safety-alert messages and their signal words (DANGER, WARNING, CAUTION, NOTICE).
Advice on seeking assistance if any portion of the sheet is not understood.
Instructions for replacing damaged or faded labels on equipment.
Details software requirements and installation for IntelliRupter PulseCloser Fault Interrupter.
Explains the use of Coordinaide software for plotting TCC curves and coordination.
Configuration related to device name, location, GPS coordinates, serial numbers, and catalog information.
Details the five commonly used functions for customized labeling on the Operation screen.
Configuration of clock synchronization source and daylight savings time settings.
Information on installed software versions and where to find updates.
Allows entering user-defined notes for the device.
Explains how Communication Enhanced Coordination (CEC) shares coordination curves and reduces customer impact during faults.
Illustrates communication-enhanced coordination for a temporary fault scenario.
Demonstrates communication-enhanced coordination for a permanent fault.
Shows CEC coordination in complex networks and after system reconfiguration.
Details setting up the initial trip parameters for overcurrent elements in Direction 1.
Explains features like Intelligent Fuse Saving (IFS) and Inverse Segment settings.
Details configuring TCC curves for test sequences for both directions.
Configuring Time Current Curves (TCCs) for coordination with downstream reclosers.
Explains that Direction 2 settings are identical to Direction 1 but for the opposite direction.
Describes performing tests to determine if a fault is temporary or permanent after an overcurrent trip.
Explains voltage trip elements and the Open-Source Sectionalizing (Positive Sequence) setting.
Details configuration settings for frequency trip elements that trigger on under or over frequency.
Explains using sectionalizing elements for fault current detection and coordination.
Describes the Hot Line Tag mode for sensitive overcurrent protection during hot-line work.
Details phase overcurrent element tripping based on inverse curve or definite time settings.
Configuration of multiple voltage trip elements within the Hot Line Tag profile.
Configuration of frequency trip elements for the Hot Line Tag profile.
Configuration of closing profiles for various operations.
Specifies the name for the Closing Profile 1 option, up to 12 characters.
Modifier that increases Minimum Trip/Low Current Cutoff values during extended outages.
Configuration for PulseClosing Technology and its manual override.
Settings for Loop Restoration mode, including directions and profile names.
Displays indications and controls for Loop Restoration mode on the Operation screen.
Step-by-step procedure to create a custom settings template for Loop Restoration mode.
Steps to configure Loop Restoration mode for a normally open feeder.
Steps to configure Loop Restoration mode for a normally closed feeder.
Specifies the Device ID for the remote device.
Configures DNP communication settings for IntelliTeam SG, SCADA, and IntelliLink.
Configuration of serial port settings like baud rate and RTS active time.
Defines routing information for up to 32 destination devices.
Configuration of Ethernet port settings, including IP address and subnet mask.
Configuration for Wi-Fi modules, including firmware version and MAC address.
Performs diagnostic tests to determine node response and communication speed.
Configures peer communication statistics and link health thresholds.
Maps DNP status points for SCADA system visibility.
Maps analog input points for SCADA system availability.
Maps control points for SCADA system operation.
Maps analog output points for SCADA system availability.
Instructions for changing default user and admin passwords and complexity rules.
Overview of the Security screen for managing user access and IntelliLink Remote Commands.
Configuration of logging levels and duplicate event margins for event data.
Evaluates settings in buffer memory without applying them for error checks.
Explains the purpose of the script for converting settings files between firmware versions.