Page #12 background imageLoading...
Page #12 background image
-12-
The LAMP REPLACE indicator will light yellow when the total lamp used time (Corresponding value) reaches 3,000
hours. This is to indicate that lamp replacement is required.
The total lamp used time is calculated by using the below expression,
Total lamp used time (Corresponding value) = Teco + (Tnormal x 1.5)
Teco: used time in the Eco1 and Eco2 mode
Tnormal : used time in the Normal mode and Auto mode
You can check the lamp used time following to the below procedure.
1 Press and hold the ON/STAND-BY button on the projector for more than 20 seconds.
2 The projector used time and lamp used time will be displayed on the screen briefly as follows.
Counter
Projector 500 H
Lamp
Normal 200 H
Eco 300 H
Corresponding value 600 H
Total lamp used time
Projector used time
How to check Lamp Used Time
Maintenance
Resetting the Lamp Counter
Be sure to reset the Lamp counter after the lamp is replaced. When the Lamp counter is reset, the LAMP RE-
PLACE indicator stops lighting and the Lamp replacement icon disappears.
Note:
Do not reset the Lamp counter without replacing the lamp. Be
sure to reset the Lamp replacement counter only after replacing
the lamp.
Press the MENU button to display the On-Screen Menu.
Use the Point 7 8 buttons to move the red frame pointer
to the Setting Menu icon
Use the Point ed buttons to move the red frame pointer
to Lamp counter and then press the SELECT button. A
dialog box appears showing the total accumulated time
of the lamp usage and the reset option. Select Reset
and the Lamp replacement counter Reset? appears.
Select [Yes] to continue.
1
2
Lamp counter
Select Reset and the “Lamp
replacement counter Reset?”
appears.
Select [Yes] again
to reset the lamp
counter.
Select [Yes], then another
confirmation box appears.
Another confirmation dialog box appears and select
[Yes] to reset the Lamp replacement counter.
3
Lamp mode

Table of Contents

Other manuals for Sanyo PLC-XP200L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-XP200L and is the answer not in the manual?

Sanyo PLC-XP200L Specifications

General IconGeneral
Vertical scan range48 - 100 Hz
Horizontal scan range15 - 100 kHz
Projection technologyLCD
Projector native resolutionXGA (1024x768)
Keystone correction, vertical±40 °
Lamp typeNSH
Lamp power330 W
Light source typeLamp
Service life of light source2000 h
Service life of light source (economic mode)3000 h
Bundled softwareUser Manual (CD ROM)
I/O portsDVI-D (digital/HDCP) D-Sub15 (RGB/SCART-RGB) 5 x BNC (RGBHV/Composite/Y-Pb/Cb-Pr/Cr) 3 x RCA (Video/Y-Pb/Cb-Pr/Cr) Mini DIN 4 (S-Video) 3.5 mm Stereo Jack D-Sub15 D-Sub9 (RS232) 3.5 mm Stereo Jack (cable remote control) USB type B
CompatibilityUXGA SXGA SXGA+ WXGA XGA S-VGA VGA Mac
Dimensions (WxDxH)370 x 440 x 187 mm
Power requirements100 - 240 V
Power consumption (standby)24.5 W
Power consumption (typical)499 W
Storage temperature (T-T)-10 - 60 °C
Operating temperature (T-T)5 - 40 °C
PlacementCeiling
Weight and Dimensions IconWeight and Dimensions
Weight11400 g
Package weight15900 g

Related product manuals