EasyManua.ls Logo

Sartorius Combics 2 CAIXS2 - Key Functions

Sartorius Combics 2 CAIXS2
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 Operating Instructions Combics CAIXS2
Operating Design
Key Functions
e On/Standby switch
When in Standby mode, STANDBY is displayed.
( Zeroing key
Press key for less than 2 seconds: Zero
Press key longer than 2 seconds: Display the adjustment/configuration
counter
) Tare key
Saves the numeric input as the tare weight
Press key longer than 2 seconds: Save the preset tare weight
k Function key: Depending on the configuration in the Setup menu, switches
between the
first and second weighing unit
results display and SQmin display.
J ISO test: Start calibration or adjustment
p Print key
Press key for less than 2 seconds: Print
Press key longer than 2 seconds: Print GMP footer
n Toggle key: When a second platform is connected (COM1), this key toggles the
display between the two readouts.
The following four keys are used for operating the individual applications. Their
exact function is described in the respective section for the application.
c Delete key: Deletes initialization values or totalizing memory. During numeric entry
the last character entered is deleted.
r Reference value key: Changes the set reference value.
O OK key: Applies values or starts an application program.
w Toggle key: Toggles between display modes within an application program.
Order no. Price in
CAIXS2
1.500
Preconfiguration with platform series CAPXS, IU, IF; verification by the manufacturer; calibration for the place of use;
mounting optional dataoutputs;
removable connection between terminal and platform can be ordered under VF2829. Please ask your sales representative.
Networking of up to 8 indicators
Suitable for: mounting on a bench, attaching to floor stand or columns,
mounting on a wall or installation in a switch cabinet
Combics 2 Ex-Indikator
Description
Combics 2 Ex-Indicator
Stainless steel housing with cable glance.
Selectable is an A/D converter or digital interface to connect one scale in total.
Standard: 1 selectable data interface RS 232/485/422
Pre-assembled adapter cable for power supply modules.
The power supply for CAIXS2 is not included in the equipment supplied (see accessories).
Explosion protected scales for hazardous areas - Combics Ex-Indicator CAIXS2
For use in Zones 1 (explosive gases) and Zone 21 (explosive dusts)
ATEX: II 2G Ex ia IIC T4 Gb
II 2D Ex ia IIIC T80°C Db
Allows the connection of one analogue Sartorius platforms Combics-Ex,
IFXS4, IUXS4, or one IS-X precision platforms, Signum Ex scale or load
cells with suitable specifications to be connected in Zone 1, 21, 20
Verifiable class III, IIII
Very easy to read display

Table of Contents

Related product manuals