EasyManua.ls Logo

SATO CL4NX - [ESC+0] Partial Edit

SATO CL4NX
756 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
57
[ESC+0] Partial Edit
ESC 0 ParameterHexadecimal code
<1B>
16
<30>
16
Nil
Initial value Nil
When the power is OFF The set command is not maintained.
Valid range within items The set command becomes invalid.
Valid range and term of
command
Valid range between items The set command becomes invalid.
[Function]
Editing the portion in the previous print data.
[Format]
<0>
[Coding Example]
[DEF], a part of print data, is changed to [123].
First label
<A>
<V>100<H>200<P>2<L>0202<XM>ABC
<V>100<H>200<P>2<L>0202<XM>DEF
<Q>1
<Z>
Second label
<A>
<0>
<V>100<H>200<P>2<L>0202<XM>123
<Q>1
<Z>
ABC
DEF
ABC
1 2 3
1st label 2nd label
Partial
edit
Label feed direction
[Supplementary Explanation]
• Use this command to edit only one part of previous print data.
• Invoke the previous print data with this command to edit and print out. In this case, specify the
part of previous data to edit, and send change data to it.
• Specified portion in the previous data will be cleared.
• If Rotation <%> is included in the specified editing portion, keep it for partial editing.
• Use this command with fixed pitch, same font or same digit number.
Parent topic Modification Command

Table of Contents

Other manuals for SATO CL4NX

Related product manuals