199
[ESC+BF] UPC Add-on (Bookland)
ESC BF ParameterHexadecimal code
<1B>
16
<42>
16
<46>
16
aabbbn...n
Initial value Nil
When the power is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range and term of
command
Valid range between items The set parameter becomes invalid.
[Function]
Specifying UPC Add-on code (Bookland).
[Format]
<BF>aabbbn...n
• Parameter
a [Narrow bar width] = Valid range : 01 to 36 dots
b [Height of barcode] = Valid range : 001 to 999 dots
n [Print data] = Numeric (0 to 9) : 2, 5 digits
[Coding Example]
Narrow bar width: 03, Barcode height: 120
<A>
<H>325<V>725<BD>H0315009827721123
<H>640<V>760<BF>0312021826
<H>655<V>730<OB>21826
<Q>1
<Z>
[Supplementary Explanation]
• If specifying the value other than 2 and 5 digits, barcode will not be printed.
• Only numeric can be specified as print data. (Refer to code table.)
• No HRI
• When printed only UPC add-on <BF>, it cannot be scanned.
Scan is available only when it is printed with UPS code.