553
[DC2+PD] Each sensor information acquisition
Command DC2 PD Parameter
Hexadecimal code <12>
16
<50>
16
<44>
16
None
Initial Value None
When turning off the power -
Valid range -
Printer operation in
progress
The command can be received even during the printer
operation.
When acquiring label
sensor information
Commands are not accepted while acquiring sensor
information. ([NAK] reply)
Valid range and term of
command
Error The command can be received even if an error is
occurring.
[Function]
This command is used to acquire the information of each sensor. The sensor information
corresponds to the information immediately after the reception of the command.
[Format]
DC2 (12H) + PD
[Return data format (normal)]
[STX]a...a,b...b:c...c,(d...d:e...e) ... [ETX]
Symbol Parameter name Valid range
a Total number of data byte
* This is the total number of bytes after parameter
b. The delimiting comma between parameters a
and b, and the ETX are not included.
Data size from the first identifier until before
[ETX]
b(d) Sensor information name
* Text format
Refer to the sensor information data list.
c(e) Sensor information data
* Text format
Refer to the sensor information data list.
Data Example)
[STX]xx,IM:0.2/SL1.5,GAP:0.9/SL1.0...[ETX]
[Return data format (when a command error occurs)]
[NAK]<15>
16