EasyManua.ls Logo

SATO S84 ex - Installation of Options; Installation of the Optional RFID Kit

SATO S84 ex
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Replacement
101
S84-ex/S86-ex Service Manual
5.20
Replacing the Timing Belt for the Optional
Ribbon Saver
Required tool:
Phillips screwdriver
1 Make sure that the printer is in power off
mode, then disconnect the power cord
from the AC outlet.
2 Open the rear housing covers from the printer.
Refer to Section 5.1.1 Opening the Rear Housing Cover for details.
3 Remove the gearbox from the printer.
Perform step 3 of Section 5.9.1 Replacing the Timing Belt of Gearbox.
4 Remove three screws and then remove the ribbon saver motor assembly
(including brackets, spring and ribbon saver motor).
5 Remove and replace the defective timing belt (Ribbon saver (160)) .
6 Perform the assembly with the reverse procedure.
After replacement
Adjust the tension of the timing belt.
Refer to
Section 4.9 Adjusting the Timing Belt Tension (Ribbon Motors, Optional Ribbon Saver
Motor)
.
2
3
1