EasyManua.ls Logo

SATO S84 ex - Replacing the Ribbon End Sensor

SATO S84 ex
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Replacement
85
S84-ex/S86-ex Service Manual
5.10
Replacing the Ribbon Sensor
Required tool:
Phillips screwdriver
1 Make sure that the printer is in power off mode, then disconnect the power cord from
the AC outlet.
2 Open the top cover of the printer.
CAUTION
Open the top cover fully to prevent accidental drop of the cover.
3 Open the rear housing covers from the printer.
Refer to Section 5.1.1 Opening the Rear Housing Cover for details.
4 Disconnect the ribbon feed sensor
cable .
5 On the front of the printer, remove the
thumbscrew attached to the cover
on top of the print head assembly.
Remove the cover and place it aside.
6 Remove two screws and the belt
cover .
1
5
4
2
3