EasyManua.ls Logo

SATO S84 ex - Replacing the Top Cover Sensor

SATO S84 ex
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Replacement
90
S84-ex/S86-ex Service Manual
5.12
Replacing the Head Open Sensor
Required tool:
Phillips screwdriver
1 Make sure that the printer is in power off
mode, then disconnect the power cord
from the AC outlet.
2 Open the rear housing covers from the printer.
Refer to Section 5.1.1 Opening the Rear Housing Cover for details.
3 Remove the gearbox from the printer.
Perform step 3 of Section 5.9.1 Replacing the Timing Belt of Gearbox.
4 Remove the screw , disconnect the
sensor cable and replace the
defective head open sensor .
5 Perform the assembly with the reverse
procedure.
Arrange and tie the cable to the cable clamp.
Make sure that the cable is not pinched.
After replacement
Check the head open error message.
Refer to Section 4.6 Checking the Head Open Error.
3
2
1
cable
clamp

Table of Contents

Other manuals for SATO S84 ex

Related product manuals