2 Operation and Configuration
12
S84-ex/S86-ex Service Manual
[Data format]
When an RTC is installed;
* Displayed in binary
When an RTC is not installed;
* Displayed in binary
[Printer status information]
Low byte
*
1
In case of command error, when command stop function is enabled, other error (55H) is replied in the
high byte and command error is not replied in the low byte.
[0] [1] [2] [3] [4] [5]
Year Month Date Hour Minute Second
[0] [1] [2] [3] [4] [5]
0 0 Millisecond
0H - FFFFFFFFH
Printer Status
Description
ASCII HEX
0 30H No warning
1 31H Ribbon near end
2 32H Buffer near full
3 33H Ribbon near end and buffer near full
4 34H
Command Error *
1
5 35H Ribbon near end and command error
6 36H Buffer near full and command error
7 37H Ribbon near end, buffer near full and command error
8 38H Label near end
9 39H Ribbon near end and label near end
: 3AH Buffer near full and label near end
; 3BH Ribbon near end, buffer near full and label near end
< 3CH Command error and label near end
= 3DH Ribbon near end, command error and label near end
> 3EH Buffer near full, command error and label near end
? 3FH Ribbon near end, buffer near full, command error and label near end
@ 40H Head error (when released and keep printing)