Chapter 6 Control system diagram
SMSO-2-02.06- 15.07.03 221
6.5.33 Refrigerator, cooling unit motor
36V 5V DC
36V S
L1, N
Operating condition
When the refrigerator is switched on (temperature controller open) the cooling unit motor is supplied with mains power.
Symptoms
The cooling unit motor and ventilator are not functioning.
Procedure
Process
step
Check Possible cause Remedy
1
Measure voltage at the connec-
tion terminals L2, N to the ma-
chine:
Mains voltage ?
Check the mains connection (see
“mains connection”)
Fault in mains connection
2
Measure voltage at plug-in con-
nection between machine and
refrigerator (interface)
Mains voltage ?
Plug contacts faulty / oxidised
Cable broken or pulled out of plug
Check / replace plug contacts
Replace cable
3
Set the temperature controller to
the highest setting, make a visual
control as to whether the ventila-
tor is running
Faulty thermostat
Faulty connecting cable to refrige-
rator or thermostate / connections
oxidised
Replace thermostat
Check / replace cable / connecti-
ons
4
The compressor should now be
operating.
Faulty starter relay
Faulty motor
Replace the starter relay
Replace the refrigerator
NO
YES
NO
YES
NO
YES
NO

Table of Contents

Other manuals for Schaerer Ambiente 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schaerer Ambiente 2 and is the answer not in the manual?

Schaerer Ambiente 2 Specifications

General IconGeneral
BrandSchaerer
ModelAmbiente 2
CategoryCoffee Maker
LanguageEnglish

Related product manuals