9. LC = 1.383257 mV/V
Non-standardized output value of the weigh cell amplifier (gross).
10. AO = 4.15 mA
Analog output current
11. ZO = 1
Pending impulses.
If the value is constantly non-zero, the impulse frequency is greater than 10Hz.
The valency of the smallest display digit 1 must be increased
(Parameter B 07).
12. ZE = 53
The impulse point output impulses displayed for an external totalizing counter, counted
as of the instruction ‘Clear Counter 1’
13. ES-Version 12
Current version of the EasyServe connected.
Service values
30 BV-H2346GB / 0833 Operating Manual INTECONT® Satus
© Schenck Process