17.4 Ethernet/IP
INTECONT® Satus is an Ethernet/IP server. You can activate the protocol and all
parameter changes specific to the protocol in the fieldbus block. You can use the unit’s
control terminal or EasyServe diagnostic tool for this.
It is connected to the network with the RJ45 plug on the basic board (refer to the chapter on
Connecting up the Unit).
The server can exchange data with as many as 16 clients at the same time. It cannot be
locked against writing access, meaning that the client most recently sending specifications
wins.
The bus interface is monitored for timeout and the defective ID configuration on the control
side as per the configuration in the fieldbus block.
17.4.1 User Data Structure
You can find details on and examples of the structure of user data in the chapter on User
Data Structure of Fieldbusses.
If you have activated (selected) one of the fieldbusses, every fault will be registered by the
‘’Communication Host’ (S9) event message if the event class IG(NORE) has been assigned
to this message. This message is visible in the display and in EasyServe. If you only have a
display available, please read the following two sections. Otherwise, EasyServe can also
supply you with more information for error diagnosis.
17.4.2 ‘Communication Host’ S 9 event message
This event message is a group message for all faults affecting the fieldbus connection.
These are:
Different station addresses sent to the master and scale.
The fieldbus cable is defective or incorrectly connected.
The timeout parameter has been set at too small a value. Change the parameterisation
of the scales.
An improper ID has been identified in the telegram from the master to the scales (only
use IDs printed in bold type)
The release bit always has to be set in the FIXED mode.
Ethernet 17.4 Ethernet/IP
INTECONT® Satus Operating Manual BV-H2346GB / 0833 87
© Schenck Process

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenck process Intecont Satus and is the answer not in the manual?

Schenck process Intecont Satus Specifications

General IconGeneral
BrandSchenck process
ModelIntecont Satus
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals