EasyManuals Logo

Schenck process Intecont Satus User Manual

Schenck process Intecont Satus
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
13.4 User data diagnosis
EasyServe provides a simplified form of a bus monitor. The dialog window can be opened
via the menu ‘Fieldbus View’. The following diagnoses are possible:
Display of the first 50 characters of the last 500 telegrams in hexadecimal format. The
display is restricted to user data only.
The following errors can be identified:
n
Incorrect data parameters. All floating point numbers will be displayed incorrectly!
n
Identifications of defective data incorrectly preset by the master
The following are not recognized:
n
Initialization error while establishing connection
n
Layer 2 problems when exchanging data
The diagram shows the EasyServe monitor display (Profibus, DeviceNet or Ethernet/IP)
Explanation:
n
The ‘Acknowledge Event’ command and the Fieldbus release bit are transmitted by the
master.
n
The reply contains all data defined in FIXED mode.
The diagram shows the Modbus telegram depiction (including Modbus frame)
Fieldbusses 13.4 User data diagnosis
INTECONT® Satus Operating Manual BV-H2346GB / 0833 67
© Schenck Process

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenck process Intecont Satus and is the answer not in the manual?

Schenck process Intecont Satus Specifications

General IconGeneral
BrandSchenck process
ModelIntecont Satus
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals