SEA SYSTEMS
INSTALLATION AND USE MANUAL
CONTROL PANEL and PREWIRED SYSTEM STK1
For Electric and Hydraulic Lifts
MSTK12-GB
Rev.01
30/12/05
SETRONIK1 Pagina 10 di 54
2.5.FIXING AND CONNECTION OF THE CONTROL PANEL
1. Drill the wall of the machine room, taking the locating holes of the angle bar
provided as a reference, so that the height at which the panel hangs makes its use
easy and convenient;
2. Anchor the angle bar to the upper section of the panel by means of appropriate
bolts and cage nuts;
3. Fasten the angle bar to the wall of the machine room with corresponding wall plugs.
HIGHLIGHT
Should the control panel be secured on premises other than the standard
machine room (ex: local cabinet, Pit, Shaft,...), the above procedure may be
inappropriate. In this case, follow the instructions specified for the system.
4. Make sure that the QM master switch is set to OFF (DOWN position);
5. Connect the appliances to the control panel as per the installation diagrams
HIGHLIGHT
The control panel has been pre-set with terminal board attachments to allow car
movements with a temporary push-button panel. Attachments to the terminal
board of both the control panel and push-button panel are outlined on the pre-
assembly diagram.