3.12.S
HAFT PROGRAMMING:
In order to modify the parameters values, it is necessary to disconnect the FA automatic
valve while, to only display the same, this is not necessary.
DG0 DG1 DG2 DG3 DG4 DG5 DG6
3
00
INTER-FLOOR TYPE (*)
00= Normal Floors
(Interfloor > 2K)
01= Short Floors
(Interfloor < 2K and > 1K)
02= Close Floors
(Interfloor < 1K and > 2 brackets)
03= Very Close Floors
(Interfloor < 2 brackets: a second bracket is
required)
INTER-FLOOR SELECTION
01= Inter-floor between floor 1 and 2
02= Inter-floor between floor 2 and 3
03= Inter-floor between floor 3 and 4
04= Inter-floor between floor 4 and 5
05= Inter-floor between floor 5 and 6
06= Inter-floor between floor 6 and 7
07= Inter-floor between floor 7 and 8
08= Inter-floor between floor 8 and 9
09= Inter-floor between floor 9 and 10
10= Inter-floor between floor 10 and 11
11= Inter-floor between floor 11 and 12
(*) = K is the slowing distance: see the layout L01 and L02.