SEA SYSTEMS
INSTALLATION AND USE MANUAL
CONTROL PANEL and PREWIRED SYSTEM STK1
For Electric and Hydraulic Lifts
MSTK12-GB
Rev.01
30/12/05
SETRONIK1 Pagina 54 di 54
7.TECHNICAL DATA
Input voltages
110 to 440 Vac (Single-phase and Three-phase)
Operating voltage
48 Vdc
Cam, electro-valves, operators
voltages
ON DEMAND
Position, arrows, out-of-service
signalling outputs
24 Vdc – 4.5W Max. Each
(With upper power see NOTE 1)
Coming, booking, Gong, Overload
signalling outputs
24 Vdc – 2.4W Max. Each
(With upper power see NOTE 2 and 3)
Occupied signalling outputs
24 Vdc – 36W Max.
Safety devices inputs
OPTO-ISOLATED (Conforming with EN 81
ED.98)
Operating temperature
0 ÷ 40 °C
Logic type
MICROPROCESSOR CONTROLLED
Data storage
PERMANENT
Re-chargeable battery
12vdc, 2 ÷ 7.5 ah (3 years life if constantly under
charge)
NOTE 1:
If the Position and Arrow signallings require a power upper than that specified upon, it’s
necessary use STK1-RO card;
NOTE 2:
If the Position Arrow and Booking signallings require a power upper than that specified upon,
it’s necessary use STK1-RV card;
NOTE 3: (electronic gong)
if the Gong absorption current exceeds 200 ma, it is necessary to put the resistor (47Ω 5w) given
with the controller in series with the gong.