EasyManua.ls Logo

SEA SETRONIK1 - 7 Technical Data

SEA SETRONIK1
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SEA SYSTEMS
INSTALLATION AND USE MANUAL
CONTROL PANEL and PREWIRED SYSTEM STK1
For Electric and Hydraulic Lifts
MSTK12-GB
Rev.01
30/12/05
SETRONIK1 Pagina 54 di 54
7.TECHNICAL DATA
Input voltages
110 to 440 Vac (Single-phase and Three-phase)
Operating voltage
48 Vdc
Cam, electro-valves, operators
voltages
ON DEMAND
Position, arrows, out-of-service
signalling outputs
24 Vdc – 4.5W Max. Each
(With upper power see NOTE 1)
Coming, booking, Gong, Overload
signalling outputs
24 Vdc – 2.4W Max. Each
(With upper power see NOTE 2 and 3)
Occupied signalling outputs
24 Vdc – 36W Max.
Safety devices inputs
OPTO-ISOLATED (Conforming with EN 81
ED.98)
Operating temperature
0 ÷ 40 °C
Logic type
MICROPROCESSOR CONTROLLED
Data storage
PERMANENT
Re-chargeable battery
12vdc, 2 ÷ 7.5 ah (3 years life if constantly under
charge)
NOTE 1:
If the Position and Arrow signallings require a power upper than that specified upon, it’s
necessary use STK1-RO card;
NOTE 2:
If the Position Arrow and Booking signallings require a power upper than that specified upon,
it’s necessary use STK1-RV card;
NOTE 3: (electronic gong)
if the Gong absorption current exceeds 200 ma, it is necessary to put the resistor (47 5w) given
with the controller in series with the gong.

Related product manuals