SETRONIK1 Pagina 42 di 54
4.3.C
OUNT OF RUNS AND RE-LEVELLINGS PERFORMED.
A).UP AND DOWN RUNS COUNT
DG0 DG1 DG2 DG3 DG4 DG5 DG6
0
0 0
NUMBER OF TENS OF RUNS
04= Count of upward runs
05= Count of downward runs
Displays DG3..DG6 show the tens of runs performed. The maximum value which can be
displayed is 9999 corresponding therefore to 99999 maximum runs.
B).EMERGENCY DOWN RUNS COUNT
DG0 DG1 DG2 DG3 DG4 DG5 DG6
0
0 6 0 0
RUNS NUMBER
The maximum number which can be displayed is 0063 (=63 runs).
C).UP AND DOWN RELEVELLINGS COUNT
DG0 DG1 DG2 DG3 DG4 DG5 DG6
0
0 0
NUMBER OF RELEVELLINGS
07= Count of upward Relevellings
08= Count of downward Relevellings
The maximum value which can be displayed is 0031 (=31 re-levellings).
N.B. Count resetting procedure:
1. Position on displays DG3..DG6. The displays continue to show the count.
2. Press .The count is reset to zero.
From now the same will start counting again.