seca 515/514
Administrator Manual
Software version 1.1 from
Build 550

Table of Contents

Questions and Answers

  • L
    landryrobertSep 18, 2025
    Why is there no access to Seca patient database of Seca 115 PC software?
    • M
      megan14Sep 18, 2025
      If there is no access to the Seca patient database of the Seca 115 PC software, it could be due to several reasons. It may be that no Seca 360° wireless network is set up between the device and the PC, or that no Ethernet connection is set up. The device could be connected to a standalone PC via an Ethernet cable, and the PC’s network card does not permit automatic crossover. Alternatively, no USB memory stick might be connected to the touchscreen display, the PC on which the Seca 115 PC software is installed might not be switched on, the Seca 115 PC software might not be started, no Seca CLS network might be set up, or the Seca CLS server of the Seca 115 PC software might not be started.
  • D
    David SimpsonAug 25, 2025
    Why aren't results report being printed from Seca 514 Medical Equipment?
    • I
      Isabel RobinsonAug 25, 2025
      If the results report is not being printed, ensure the PC printer is switched on, the PC on which the Seca 115 PC software is installed has been switched on, and a link has been set up between the Seca 115 PC software and the PC printer.
  • H
    hayscynthiaAug 25, 2025
    What to do if the message ER11 appears on Seca 514?
    • S
      stephen82Aug 26, 2025
      If the message ER11 appears on your Seca Medical Equipment, it indicates that the device is overloaded either as a whole or in one corner. To resolve this, remove the load or distribute it evenly and then restart the device.
  • S
    Sarah GayAug 27, 2025
    What does message ER12 mean on Seca 514 and how to fix it?
    • M
      Mrs. Heather BeckAug 27, 2025
      If the Seca Medical Equipment displays the message ER12, it means the device was switched on with too heavy a load. To fix this, remove the load from the device and then restart it.
  • J
    Jeremy StephensSep 18, 2025
    Why is there no access to Seca patient database with USB connected to Seca 514 Medical Equipment?
    • E
      Ebony CordovaSep 18, 2025
      If a USB memory stick is connected to the touchscreen display but there is no access to the Seca patient database, it may be due to several reasons. A non-initialized USB memory stick may be in use, a PIN may not have been entered or was entered incorrectly, an unsuitable USB memory stick may be in use, or there may be interference from high-frequency emissions from other devices. Ensure you are using the supplied USB memory stick or a FAT16 USB memory stick, that you enter your user PIN or the PIN for the USB memory stick correctly, and that you increase the distance from high-frequency devices.
  • E
    ellisaaronSep 23, 2025
    Why is there no height in the results report from Seca 514?
    • D
      dillonmayerSep 23, 2025
      If there is no height in the results report, it is because no height was entered on the device. Call up the weight/height tab and enter the height.
  • T
    Tiffany GilbertSep 9, 2025
    What does 'Electrode detection failed' mean on Seca Medical Equipment and how to resolve it?
    • R
      Robert MillsSep 9, 2025
      If the following message appears on your Seca Medical Equipment: “Electrode detection failed,” it may be due to the patient’s skin being too dry or too calloused. In this case, spray the skin at the contact points with electrode spray. If the issue persists, the electrodes may be faulty, and you should inform Seca service.
  • M
    Mark KhanSep 10, 2025
    Why is an evaluation parameter value shown in red on Seca 514?
    • N
      noblekristiSep 10, 2025
      If a value of an evaluation parameter is shown in red on your Seca Medical Equipment, it indicates that the value is outside the normal range determined for that parameter. Repeat the measurement to rule out any measurement errors. If the repeat measurement also produces a value outside the normal range, consider this value in further investigations.
  • M
    Maria GreerSep 3, 2025
    Why doesn't 0.00 appear before weighing on my Seca 514?
    • T
      Travis LucasSep 3, 2025
      If 0.00 does not appear before weighing on your Seca Medical Equipment, it indicates that the device had a load on it before it was switched on. Remove the load from the device, switch it off, and then switch it back on again.
  • C
    Cynthia MillerSep 1, 2025
    What to do if the image on Seca 514 Medical Equipment touchscreen display is faulty?
    • J
      Jessica BlackSep 1, 2025
      If the image on the touchscreen display of your Seca Medical Equipment is faulty, the touchscreen display itself may be faulty. In this case, inform Seca service.

Summary

Device Description

Intended Use

Explains the primary purpose and application areas of the medical Body Composition Analyzer.

Functionality and Features

Details the device's capabilities, including weight, height, and bioimpedance measurements.

Contraindications

Lists conditions or situations where bioimpedance measurements should not be performed.

Safety Information

General Safety Instructions

Provides essential safety guidelines for operating the device safely and preventing hazards.

Patient Safety and Device Integrity

Covers precautions against electric shock, injuries, infections, device damage, and result integrity.

Packaging Handling

Instructions for handling and storing the device's packaging.

Device Overview

Controls and Indicators

Identifies and explains the device's physical controls, buttons, LEDs, and display symbols.

Color Symbols and Other Controls

Details the meaning of various color symbols and control elements on the device interface.

Menu Structure and Navigation

Outlines the hierarchical structure of the device's menus and how to navigate through them.

Device and Type Plate Identification

Explains the markings and labels found on the device and its type plate.

Packaging Identification

Describes the symbols and information found on the product packaging.

Making the Device Operational

Scope of Delivery and Initial Setup

Lists all included components and guides through the initial power connection and setup.

Device Setup and PC Network Integration

Covers device placement, network connection via Ethernet or wireless, and PC software integration.

Operation with seca 360° Stadiometer

Explains how to use a seca 360° stadiometer for height measurement wirelessly.

Operating Concept

User Interface and Basic Operations

Details touchscreen operation, switching on/off, selecting functions, and data entry methods.

Measurement Procedure and Device States

Guides through the typical measuring process, including assigning patients and saving results.

Automatic Standby and Switching Off

Explains the device's automatic standby feature and the procedure for safely switching it off.

Configuring the Device

Bioimpedance Measurement Configuration

Guides on adapting default module selection for bioimpedance analysis.

User Administration and Access Control

Covers setting up user accounts, PINs, passwords, and accessing the Administrator menu.

System and Network Settings

Details configuring units, regional settings, date/time, and network parameters.

Display Settings and Network Setup

Covers adjusting display brightness/volume and setting up Ethernet and wireless networks.

Ethernet Network Integration

Step-by-step guide to integrate the device into an Ethernet network.

Securing CLS Network Communication

Instructions for setting up the seca CLS network for PC communication.

Securing 360° Wireless Network

Detailed steps for setting up a seca 360° wireless network connection.

Viewing Wireless Device Status

Explains how to view connected wireless devices and their status.

System Data and Software Versions

Information on viewing software versions, scale logbook, and making system settings.

Exporting System Log File

Procedure for exporting system log files for analysis and troubleshooting.

Administrator PIN and Touchscreen Calibration

Steps for changing the administrator PIN and calibrating the touchscreen display.

Restoring Factory Settings

Guide on how to reset the device to its original factory default settings.

Service Functions and Software Updates

Details on using service functions like software updates and exporting/importing settings.

Troubleshooting

Power, Display, and Basic Operation Issues

Addresses problems related to power, dark/unresponsive displays, and initial weighing.

Bioimpedance Analysis and Measurement Errors

Solutions for bioimpedance-specific errors, module activation, and result deviations.

Data Transmission and Connectivity Problems

Troubleshoots issues with setting up device-to-PC communication and patient file access.

Print Function and Reporting Issues

Solves problems related to print function availability and report generation.

Optional Accessories

Spare Parts

Technical Information

Wireless Network Specifications

Provides technical details about the seca 360° wireless network capabilities.

Software Compatibility and Modifications

Details compatibility between device and PC software versions and recent modifications.

Disposal, Warranty, and Conformity

Seca 514 Specifications

General IconGeneral
BrandSeca
Model514
CategoryMedical Equipment
LanguageEnglish

Related product manuals