Operating instructions Distance sensors Dx35
Electrical connection
24 © SICK AG • Subject to change without notice • 8014868/YEF7/2014-09-02
7 Electrical connection
7.1 Safety
Incorrect supply voltage
NOTICE
Equipment damage due to incorrect supply voltage!
An incorrect supply voltage may result in damage to
the equipment.
For this reason:
Operate the distance sensor using only safety extra-
low voltage.
The power supply must ensure safe electrical isolation
(SELV/PELV) and limit the current to a maximum of 8 A.
Working with live parts
NOTICE
Equipment damage or unpredictable operation due to
working with live parts!
Working with live parts may result in unpredictable
operation.
For this reason:
Only carry out wiring work when the power is off.
Only connect and disconnect cable connections when
the power is off.
7.2 Wiring notes
NOTICE
Faults due to incorrect wiring!
Incorrect wiring may result in operational faults.
For this reason:
Follow the wiring notes precisely.
NOTE
We recommend using pre-assembled cables for
the wiring. For pre-assembled cables, see Page 60,
Chapter 14.1.