5 10 20 50 D [m]
d [mm]
1000
500
200
100
50
20
10
2
3
64
Figure 90: Scanning range and object size for warning fields (devices with a max. protective field
r
ange of 9.0m)
d Required minimum size of the object in mm
D Scanning range in m
2
Scan cycle time = 40ms
3
Scan cycle time = 50ms
TECHNICAL DATA 13
8020200/1NTM/2024-06-03 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™