Range for warning fields
F
or non-safety applications (warning fields), the safety laser scanner has a larger scan‐
ning range than the maximum protective field range. The requirements for size and
remission factor of objects to be detected are illustrated in the following graphs as a
function of the desired scanning range.
5 10 20 50 D [m]
d [mm]
1000
500
200
100
50
20
10
2
1
Figure 89: Scanning range and object size for warning fields (devices with a max. protective field
r
ange of 4.0m and devices with max. protective field range of 5.5m)
d Required minimum size of the object in mm
D Range in m
1
Scan cycle time=30ms
2
Scan cycle time = 40ms
13 T
ECHNICAL DATA
178
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™ 8020200/1NTM/2024-06-03 | SICK
Subject to change without notice