350mm into account in this direction.
3
)
Supplement Z
R
must be upheld at least at a
width of 3 × d (d = set object resolution) around the laser beam which hits the surface
vertically.
Supplement C
R
O
to protect against reaching over
Under certain circumstances, a person can reach the hazardous area by reaching over,
before the protective device stops the dangerous state. Supplement C
RO
prevents this.
Figure 27: Protection against reaching over when mounted low (dimensions in mm)
Figure 28: Protection against reaching over when mounted high (dimensions in mm)
T
he necessary supplement to the minimum distance depends on the height of the
protective field’s scan plane. The supplement is larger if the safety laser scanner is
affixed low-down than if it is affixed high-up.
3)
The protective field range depends on the set scan cycle time and resolution.
PROJECT PLANNING 4
8020200/1NTM/2024-06-03 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherNet/IP™
37
Subject to change without notice