Chapter 9
Power-up delay 60 s
Of a configured device 15 s
Configurable restart after 2 s 60 s
General data
Laser protection class Laser class 1 according to
IEC 60825F1 (2007F3) (complies with
21 CFR 1040.10 and 1040.11 except for
deviations pursuant to Laser Notice No. 50,
June 2007)
Enclosure rating As per EN 60529 (1991F10); A1 (2002F02)
LMS500 IP 65
LMS511 IP 67
EMC test As per EN 61000F6F2 (2005F08),
EN 61000F6F3 (2007F03)
Electrical safety As per EN 50178 (1997F10)
Operating temperature range
LMS500 0 °C (32 °F) +50 °C
(122 °F)
LMS511 –30 °C
(–22 °F)
+50 °C
(122 °F)
Storage temperature range –30 °C
(–22 °F)
+70 °C
(158 °F)
max. 24 h
Humidity (taking into account the operating
temperature range)
DIN EN 60068F2F61, method 1
Vibration resistance As per EN 60068F2F6 (1995F04)
Frequency range 10 Hz 150 Hz
Amplitude 5 g RMS
Shock resistance As per EN 60068F2F27 (1993F03),
EN 60068F2F29 (1993F04)
Single shock 15 g (0.53 oz), 11 ms
Continuous shock 10 g (0.35 oz), 16 ms
Sender Pulsed laser diode
Wave length 895 nm 905 nm 915 nm
Divergence of the collimated beam (solid angle)
High resolution
Standard resolution
3.6 mrad
11 mrad
Housing
Material GDFALSI12 3.2582.05
Colour LMS500 RAL 5012 (blue)
Colour LMS511 RAL 7032 (grey)
Alloy Excellent weather resistance as per DIN EN
106:1988, plate 3
Front screen
Material Polycarbonate
Surface finish Outside with scratch-resistant coating