2.7 Operational safety and particular hazards
Please observe the safety notes and the warnings listed here and in other sections
of this production documentation to reduce the possibility of risks to health and avoid
dangerous situations.
The product is fitted with LEDs in risk group 0. The accessible radiation from these
LEDs does not pose a danger to the eyes or skin.
Operating the product in conjunction with external illumination systems may result in
hazardous radiation exposure. Please note the accompanying production documenta‐
tion.
WARNING
Electrical voltage!
Electrical voltage can cause severe injury or death.
Work on electrical systems must only be performed by qualified electricians.
The power supply must be disconnected when attaching and detaching electrical
connections.
The product must only be connected to a voltage supply as set out in the require‐
ments in the operating instructions.
National and regional regulations must be complied with.
Safety requirements relating to work on electrical systems must be complied with.
WARNING
Risk of injury and damage caused by potential equalization currents!
Improper grounding can lead to dangerous equipotential bonding currents, which may
in turn lead to dangerous voltages on metallic surfaces, such as the housing. Electrical
voltage can cause severe injury or death.
Work on electrical systems must only be performed by qualified electricians.
Follow the notes in the operating instructions.
Install the grounding for the product and the system in accordance with national
and regional regulations.
2.8 Laser safety
Whenever a laser module is used in combination with a 3D camera, the camera is
considered to be a part of a laser system. This system has to incorporate additional
safety features, depending on the applicable laser class. Refer to the safety instructions
of the manufacturer of the used laser module.
WARNING
When a SICK device is used in combination with a laser, all requirements for laser
products and laser systems according to the laser safety standards EN/IEC 60825–1
and 21 CFR 1040.10/11 must be fulfilled.