EasyManua.ls Logo

SICK Ranger3

SICK Ranger3
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Type Description Visibility Access
Scan3dRectificationMe‐
thod[Scan3dExtractionSelector]
enum Defines how the rectification output in a bin is created
from (potentially) multiple calibrated entries.
Values:
TopMost
BottomMost
Guru RW
1
Availability depending on device type, region and method
16.2.4 Acquisition control
Table 18: Acquisition control standard SFNC selector
Selector Type Description Visibility
TriggerSelector enum Selects the type of trigger to configure.
Value:
LineStart
FrameStart
ExposureStart
AreaScanFrameStart
Beginner
Table 19: Acquisition control standard SFNC parameters
Parameter Type Description Visibility Access
AcquisitionMode enum Sets the acquisition mode of the device. It defines
mainly the number of frames to capture during an
acquisition and the way the acquisition stops.
Values:
SingleFrame
Continuous
Beginner RW
AcquisitionStopMode enum Controls how the AcquisitionStop command and the
acquisition stopped using a trigger (e.g. AcquisitionAc‐
tive, FrameBurstActive, FrameActive or FrameEnd trig‐
ger), ends an ongoing frame.
Values:
Complete
Immediate
Expert RW
AcquisitionFrameRate float Controls the acquisition rate (in Hertz) at which the
frames are captured.
Valid if DeviceScanType is Areascan.
Beginner R(W)
AcquisitionLineRate float Controls the rate (in Hertz) at which the lines in a frame
are captured.
Valid if DeviceScanType is Linescan3D and no external
line trigger is active.
Beginner R(W)
TriggerMode[TriggerSelector] enum Controls if the selected trigger is active.
Values:
On
Off: running on timer controlled via Framerate/Lin‐
erate.
Beginner RW
TriggerSource[TriggerSelector] enum Specifies the internal signal or physical input line to use
as the trigger source. The selected trigger must have its
TriggerMode set to On.
Values:
Encoder
FrameTriggerInput
LineStart
LineTriggerInput
Beginner R
16 ANNEX
100
O P E R A T I N G I N S T R U C T I O N S | Ranger3 8020774/1D7Q/2022-03 | SICK
Subject to change without notice

Table of Contents