7 Electrical installation
7.1 Conditions for specified enclosure rating
To ensure compliance with the IP65 and IP67 enclosure rating of the device during
operation, the following requirements must be met:
The cables plugged into the electrical M12 connections must be screwed tight.
The optics protective hood must be screwed tightly onto the device.
Any electrical M12 connections that are not being used must be sealed with
protective plugs that are screwed tight (as in the delivery condition).
7.2 Wiring instructions
NOTE
Pre-assembled cables can be found online at:
www.sick.com/Ranger3
NOTICE
Faults during operation and device or system defects!
Incorrect wiring may result in operational faults and defects.
Follow the wiring notes precisely.
Observe the following safety measures:
Standard safety requirements must be met when working in electrical systems.
Only connect and disconnect electrical connections when there is no power to the
system. Otherwise, the devices may be damaged.
Use only shielded cables. The shield has to be terminated at both ends of the
cable.
Ensure that loose cable ends are isolated.
Connect unused pins to GND.
Wire cross sections of the supply cable from the customer's power system should
be designed and protected in accordance with the applicable standards.
Make sure that the Power-I/O cable is protected by a separate slow-blow fuse with
a maximum rating of 2.0 A. This fuse must be located at the start of the supply
circuit.
The 24 V voltage supply must meet the requirements of SELV+LPS relating to "UL/
EN60950-1:2014-08", or ES1 according to "EN/UL62368", or "CAN/CSA-C22.2
No 223-M91(R2008)-Power supplies with Extra-Low-Voltage class 2 outputs", or
"UL1310 (6th Edition)-standard for class 2 power units".
All circuits connected to the device must be designed as ES1 circuits (according
to EN/UL62368) or as SELV (Safety Extra Low Voltage) circuits (according to EN/
UL60950).
Connect the connecting cables in a de-energized state. Switch on the supply
voltage only after complete installation/connection of all connecting cables to the
device and control system.
7
ELECTRICAL INSTALLATION
22
O P E R A T I N G I N S T R U C T I O N S | Ranger3 8020774/1D7Q/2022-03 | SICK
Subject to change without notice