Parameter Type Description Visibility Access
RegionMode[RegionSelector] enum Controls if the selected region of interest is active and
streaming.
Values:
Off
On
Expert R
2
BinningVertical int Number of vertical photo-sensitive cells to combine
together. This reduces the vertical resolution (height)
of the image.
Expert R(W)
ComponentEnable[RegionSelec‐
tor][ComponentSelector]
bool Controls if the selected component streaming is active. Beginner RW
PixelFormat[RegionSelector][Com‐
ponentSelector]
enum Format of the pixels provided by the device.
Values:
Mono4, Mono8, Mono10p, Mono12p, Mono16
Coord3D_C8, Coord3D_C10p, Coord3D_C12p,
Coord3d_C16
Coord3D_A8, Coord3D_A12p, Coord3D_A10p,
Coord3D_A16
Coord3D_AC8_Planar,
Coord3D_AC10p_Planar,
Coord3D_AC12p_Planar,
Coord3D_AC16_Planar
Beginner R(W)
TestPattern[RegionSelector][Com‐
ponentSelector]
enum Selects the type of test pattern that is generated by the
device as image source.
Values:
Off
GreyHorizontalRampMoving
Beginner R(W)
RegionIDValue[RegionSelector] int The unique identifier value corresponding to the
Region.
Expert R
ComponentIDValue[Component‐
Selector]
int The unique identifier value corresponding to the
selected Component type.
Expert R
1
According to GeniCam™ SFNC, the ExposureTime parameter belongs to the AcquisitionControl category. Here it is moved to the ImageFormat‐
Control category because it is selected by the RegionSelector parameter.
2
Controlled by parameter DeviceScanType
3
Availability depending on device type, region and component
Table 14: Image format control custom parameter
Parameter Description Visibility Access
RegionDescription[RegionSelector] Describes the usage of a specific region in the device. Beginner R
16.2.3 Scan 3D control
Table 15: Scan 3D control standard SFNC selectors
Selector Type Description Visibility
Scan3dExtractionSelector enum Selects the 3DExtraction processing module to control
(if multiple ones are present).
Value:
Scan3dExtraction1
Scan3dExtraction2
Scan3dExtraction3
Scan3dExtraction4
Scan3dExtraction5
Beginner
16 ANNEX
96
O P E R A T I N G I N S T R U C T I O N S | Ranger3 8020774/1D7Q/2022-03 | SICK
Subject to change without notice