EasyManua.ls Logo

SICK Ranger3

SICK Ranger3
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0
0 100 200 300 400 500 600 700 800 900 1000 1100
Number of rows
Line rate (kHz)
5
10
15
20
25
30
35
40
45
50
1
2
3
4
5
6
Figure 76: The maximum line rate as a function of the number of sensor rows used
1
Line rate (kHz)
2
Number of rows
3
Ranger3-60, 2560 columns
4
Ranger3-40, 2560 columns
5
Ranger3-30, 1536 columns
6
Bandwidth limitation for 2560 columns
13.4 Interfaces
Product Ranger3-60 Ranger3-40 Ranger3-30
Configuration software Ranger3 Studio
Communication interfaces Gigabit Ethernet/GigE Vision
Operating system Windows 10
Programming interface GenAPI, GenTL
Digital inputs 4 x HIGH = 10 V ... 28.8 V
Digital outputs 2 x TTL level for laser strobe
Encoder interface RS-422 (5V level)
External illumination con‐
trol
2 x 5 V TTL
13.5 Ambient data
Product Ranger3-60 Ranger3-40 Ranger3-30
Shock load 15 g, 3 x 6 directions
Vibration load 5 g, 58 Hz ... 150 Hz
Ambient operating temper‐
ature
0 °C ... +50 °C
1
Ambient storage tempera‐
ture
–20 °C ... +70 °C
1
1
Non-condensing
13 TECHNICAL DATA
82
O P E R A T I N G I N S T R U C T I O N S | Ranger3 8020774/1D7Q/2022-03 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK Ranger3

Related product manuals