0
0 100 200 300 400 500 600 700 800 900 1000 1100
Number of rows
Line rate (kHz)
5
10
15
20
25
30
35
40
45
50
1
2
3
4
5
6
Figure 76: The maximum line rate as a function of the number of sensor rows used
1
Line rate (kHz)
2
Number of rows
3
Ranger3-60, 2560 columns
4
Ranger3-40, 2560 columns
5
Ranger3-30, 1536 columns
6
Bandwidth limitation for 2560 columns
13.4 Interfaces
Product Ranger3-60 Ranger3-40 Ranger3-30
Configuration software Ranger3 Studio
Communication interfaces Gigabit Ethernet/GigE Vision
Operating system Windows 10
Programming interface GenAPI, GenTL
Digital inputs 4 x HIGH = 10 V ... 28.8 V
Digital outputs 2 x TTL level for laser strobe
Encoder interface RS-422 (5V level)
External illumination con‐
trol
2 x 5 V TTL
13.5 Ambient data
Product Ranger3-60 Ranger3-40 Ranger3-30
Shock load 15 g, 3 x 6 directions
Vibration load 5 g, 58 Hz ... 150 Hz
Ambient operating temper‐
ature
0 °C ... +50 °C
1
Ambient storage tempera‐
ture
–20 °C ... +70 °C
1
1
Non-condensing
13 TECHNICAL DATA
82
O P E R A T I N G I N S T R U C T I O N S | Ranger3 8020774/1D7Q/2022-03 | SICK
Subject to change without notice