3. In the Image workflow step, click Start to view the 2D images and the laser line.
9.2.1.1 Editing IP settings
Before you connect to the camera, you can set non-persistent IP address, subnet mask,
and gateway. These settings will be lost if the camera is restarted.
When you have connected to the camera, you can edit the corresponding parameters to
make the settings persistent, that is, save them in the camera's flash memory.
Non-persistent IP settings
Workflow step: Cameras
1. Select the correct camera and click IP settings.
A new window opens.
Figure 51: IP settings
2. To get suggested IP settings from the system, click GevDeviceProposeIP.
3. If needed, edit the suggested settings.
4. To save the IP settings, click GevDeviceForceIP.
5. Close the window.
6. To update the IP settings and the device status, click Scan.
Persistent IP-settings
Workflow step: Image, Data collection
1. Open the Parameter editor and go to the TransportLayerControl category.
2. In the GigE vision sub-category, select the GevCurrentIPConfigurationPersistent IP check
box and then edit the GevPersistentIPAddress, GevPersistentSubnetMask, and GevPersis‐
tentDefaultGateway parameters.
3. Restart the camera to apply the updated parameters.
9.2.2 Adjusting focus
Workflow step: Image