7.6 Connecting a CDB650-204
The Connection Device Basic (CDB) offers options for quickly connecting one sensor, via
host PCs or PLCs, in accordance with industrial standards. Both the sensor and the
connection module meet all IP 65 enclosure rating requirements for dust and water
spray protection.
A 2A fuse is included in the CDB. If another connection method is used, a 2A fuse
needs to be added to the installation.
Please refer to the CDB650 Operating Instruction before connecting the Ranger3 to the
CDB.
Figure 11: Electrical connections for CDB650-204
1
Cable gland, 5 x
2
17-pin M12 female connector, A-coded
Figure 12: Connection ports for CDB650-204
Terminal in
CDB650
Signal in Ruler3000 Voltage
1
50 I/O 3 24 V input
2
51 I/O 4 24 V output
3
10 I/O 1 24 V input
4
13 I/O 2 24 V input
ELECTRICAL INSTALLATION 7