Line Modules Booksize
4.4 Active Line Modules with cold plate
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
213
25-5AA3 +
Active
Interface
Module
Active Line Module
μF
710
1410
1880
1880
2820
3760
Circuit breaker
(IEC 60947 and UL)
See Section Overcurrent protection using line fuses and circuit breakers
-
4)
kA 65 65 65 65 65 65
Max. permissible heat sink
temperature
° C 70 73 83 83 75 80
without derating
° C
40
40
40
40
40
40
Derating must be applied due to the transfer of heat to the external heat sink. At a temperature of 40° C at the interface
to the power unit, 80% derating occurs for 6SL3136-7TE28-0AAx and 70% for 6SL3136-7TE31-2AAx
The specified power ratings apply to the line voltage range from 380 V to 480 V.
Default for 400 V line systems; undervoltage trip threshold is adjusted to the parameterized rated voltage
The resulting rated short-circuit current is obtained from the combination of the fuse or circuit breaker – and the Line
Module in the drive system.
kW and 120 kW Active Line Modules should ideally be designed with
kW Active Line Modules Liquid Cooled in order to avoid power derating.