Line Modules Booksize
4.4 Active Line Modules with cold plate
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
213
Cold plate
6SL3136-
7TE
21-6AAx
23-6AAx
25-5AAx
25-5AA3 +
Active
Interface
Module
28-0AAx
31-2AAx
DC link capacitance
Active Line Module
Drive line-up, max.
μF
μF
710
20000
1410
20000
1880
20000
1880
20000
2820
20000
3760
20000
Power factor
cosϕ
1
1
1
1
1
1
Circuit breaker
(IEC 60947 and UL)
See Section Overcurrent protection using line fuses and circuit breakers
(Page 51)
Rated short-circuit
-
current
SCCR
4)
kA 65 65 65 65 65 65
Max. permissible heat sink
temperature
° C 70 73 83 83 75 80
Max. ambient temperature
without derating
with derating
° C
° C
40
55
40
55
40
55
40
55
40
55
40
55
Weight
kg
6.1
10.2
13.8
13.8
20.3
20.4
1)
Derating must be applied due to the transfer of heat to the external heat sink. At a temperature of 40° C at the interface
to the power unit, 80% derating occurs for 6SL3136-7TE28-0AAx and 70% for 6SL3136-7TE31-2AAx
2)
The specified power ratings apply to the line voltage range from 380 V to 480 V.
3)
Default for 400 V line systems; undervoltage trip threshold is adjusted to the parameterized rated voltage
4)
The resulting rated short-circuit current is obtained from the combination of the fuse or circuit breaker and the Line
Module in the drive system.
Note
New systems with 80
kW and 120 kW Active Line Modules should ideally be designed with
120
kW Active Line Modules Liquid Cooled in order to avoid power derating.