Motor Modules Booksize
6.4 Motor Modules with cold plate
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
457
Table 6- 42 Technical data Single Motor Modules Booksize (3 to 30 A)
Rated current (I
n
)
Base-load current (I
H
)
Intermittent duty current (I
S6
)
40%
max
A
ACrms
A
A
ACrms
A
ACrms
2,6
3,5
6
4,3
6
10
7,7
10
18
15,3
24
36
25,5
40
56
0 … 0.717 x DC-link voltage
d max
DC
DC-link voltage
(up to 2000 m above sea level)
V
DC
510 … 720
Overvoltage trip
2)
V
DC
820 ± 2 %
DC
Electronics current drawn
at 24 VDC
DC
Current carrying capacity
DC-link busbars
Reinforced DC-link busbars
24 VDC busbars
A
DC
A
DC
100
150
3)
Based on I
n
(600 VDC; 4 kHz)
H
kW
1,6
2,7
4,8
9,7
16
(including electronics losses, see
Power loss tables (Page 781))
W 45,5 70,6 95,6 180,6 305,6
without derating
kHz
4
without derating
° C
40
Max. permissible heat sink
temperature
° C 80 80 80 80 70
Applies only to order numbers with x = 0 .. 3
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V and is adjusted to the
parameterized rated voltage
3)
Rated power of a typical standard induction motor at 400 V 3 AC.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com