466 Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Double Motor Modules (300% overload)
Table 6- 46 Technical data Double Motor Modules (2 x 3 to 2 x 9 A) with 300% overload
Rated current (I
n
)
Base-load current (I
H
)
Intermittent duty current (I
S6
) 40%
max
A
ACrms
A
A
ACrms
ACrms
2 x 2.6
2 x 3.5
2 x 4.3
2 x 6
2 x 7.7
2 x 10
d max
DC
DC-link voltage (up to 2000 m above sea level)
Overvoltage trip
1)
V
DC
820 ± 2 %
DC
Electronics current drawn
at 24 VDC
Current carrying capacity
DC-link busbar
Reinforced DC-link busbars
A
DC
A
DC
DC
100
150
100
150
100
150
2)
Based on I
n
(600 VDC; 4 kHz)
H
kW
2 x 1.6
2 x 2.7
2 x 4.8
(including electronics losses, see Power loss
W 91,6 126,6 181,6
without derating
kHz
4
without derating
° C
40
Max. permissible heat sink temperature
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V and is adjusted to the
parameterized rated voltage
2)
Rated power of a typical standard induction motor at 400 V 3 AC.