Motor Modules Booksize
6.4 Motor Modules with cold plate
Booksize Power Units
458 Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Table 6- 43 Technical data Single Motor Modules (45A to 200A)
Cold plate
6SL3126-
1TE24-5AAx
1TE26-0AAx
1TE28-5AAx
1TE31-3AAx
1TE32-0AAx
Output current
Rated current (I
n
)
Base-load current (I
H
)
Intermittent duty current (I
S6
)
40%
Peak current (I
max
)
A
ACrms
A
A
ACrms
A
ACrms
45
38
60
85
60
51
80
113
85
68
110
141
132
(105)
1)
105 (84)
1)
150 (120)
1)
210
200
(140)
1)
141 (99)
1)
230 (161)
1)
282
Output voltage
V
ACrms
0 … 480
DC-link current I
d max
A
DC
54
72
102
158
200
DC-link voltage
(up to 2000 m above sea level)
V
DC
510 … 720
DC-link capacitance
μF
1175
1410
1880
2820
3995
Overvoltage trip Undervoltage
trip
2)
V
DC
V
DC
820 ± 2 %
380
Electronics power supply
V
DC
24 (20,4 … 28,8)
Electronics current drawn
at 24 VDC
A
DC
0,75
0,75
0,8
0,85
0,85
Current carrying capacity
DC-link busbars
24 VDC busbars
A
DC
A
DC
200
20
Unit rating
3)
Based on I
n
(600 VDC; 4 kHz)
Based on I
H
kW
kW
24
21
32
28
46
37
71 (57)
1)
57 (46)
1)
107 (75)
1)
76 (53)
1)
Total power loss
(including electronics losses, see
Power loss tables (Page 781))
W 448 608 769,2 1270,4 2070,4
Max. pulse frequency
without derating
with derating
kHz
kHz
4
16
Max. ambient temperature
without derating
with derating
° C
° C
40
55
Max. permissible heat sink
temperature
° C 80 73 83 75 79
(70%
derating)
Weight
kg
9,1
9,1
12,5
18,0
18,0
1)
Derating must be applied due to the transfer of heat to the external heat sink. At a temperature of 40° C at the interface
to the power unit, 80% derating occurs for 6SL3126-1TE31-3AAx and 70% for 6SL3126-1TE32-0AAx.
2)
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V (exception: 132 A and 200 A
Motor Modules) and is adjusted to the parameterized rated voltage.
3)
Rated power of a typical standard induction motor at 400 V 3 AC.
Note
New systems with 132
A and 200 A Motor Modules should ideally be designed with 200 A
liquid
-cooled Motor Modules in order to avoid current derating.