Motor Modules Booksize
6.2 Motor Modules with internal air cooling
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
387
Table 6- 12 Technical data Single Motor Modules Booksize (45 to 200 A)
Rated current (l
n
)
Base-load current (I
H
)
Intermittent duty current (I
s6
)
40%
max
A
ACrms
A
A
ACrms
A
ACrms
38
60
85
51
80
113
68
110
141
105
150
210
141
230
282
0 … 0.717 x DC-link voltage
d max
DC
(up to 2000 m above sea level)
V
DC
510 … 720
Overvoltage trip
1)
V
DC
820 ± 2 %
DC
Electronics current drawn
at 24 VDC
DC
Current carrying capacity
DC-link busbars
A
DC
200
200
200
200
200
2)
Based on I
n
(600 VDC; 4 kHz)
H
kW
24
32
46
71
107
(including electronics losses, see
Power loss tables (Page 781))
W 455,2 615,2 786 1270,4 2070,4
without derating
kHz
4
without derating
° C
40
Cooling method (with fan)
3
Max. permissible heat sink
temperature
° C 85 90 83 70 80
(70%
kg 9 9 15 21 21
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V (exception: 132 A and 200 A
Motor Modules) and is adjusted to the parameterized rated voltage.
2)
Rated power of a typical standard induction motor at 400 V 3 AC.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com