Safety Integrated
4.2 SINUMERIK Safety Integrated
Guide for the SINUMERIK 840D sl machine configuring
4-12 Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
Electronics module 4 F-DO 24 VDC/2 A PROFIsafe
The actuators that must be shut-down in a safety-related fashion are connected through two
channels. Each output channel can be separately shutdown.
Two valve units are connected in the configuration example. These are used to control the
motion of the supplementary pneumatic axis.
'23
'20
'23
'20
3RVVLEO\SURFHVVIHHGEDFNIRU
IRUFHGG\QDPL]DWLRQIHGWR3/&
LQSXW
3RVVLEO\SURFHVVIHHGEDFNIRU
IRUFHGG\QDPL]DWLRQIHGWR3/&
LQSXW
9DOYH
XQLW
9DOYH
XQLW
Figure 4-7 Signal assignment electronics module, 4F-DO, 24 VDC_2 A, PROFIsafe