EasyManuals Logo

Siemens SCALANCE X-400 Configuration Manual

Siemens SCALANCE X-400
404 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
Configuration using Web Based Management and Command Line Interface
4.4 The Agent menu
SCALANCE X-300 / X-400
106 Configuration Manual, 10/2014, C79000-G8976-C187-22
4.4.5
Agent Event Configuration
System events of the IE switch
On this page, you specify how an IE switch reacts to system events. By enabling the
appropriate check boxes, you specify which events trigger which reactions on the IE switch.
The following options are available:
The IE switch sends an E-mail.
The IE switch triggers an SNMP trap.
The IE switch writes an entry in the log file.
The IE switch writes an entry to the Syslog server.
Figure 4-36 Agent Event Configuration
You can configure the reaction of the IE switch to the following events:
Cold/Warm Start
The IE Switch was turned on or restarted by the user.
Link Change
A port has failed or data traffic is being handled again over a port that had previously failed.