Configuration using Web Based Management and Command Line Interface
4.7 The Router menu (SCALANCE X414-3E)
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
299
Command
Description
Comment
edit <areaID> [type] [E|D]
[metric]
Modifies an area.
Possible types:
• Standard
• Stub
• NSSA
The [E|D] and metric parameters are possible
only for a stub area.
• E
Enable importing summary
• D
Disable importing summary
Administrator only.
delete <areaID>
Deletes an area
Administrator only.
Example
The command
add 0.0.0.3 Stub d 2
generates a stub area "0.0.0.3" for which no summary LSAs are generated. The default
route is assigned metric "2".
4.7.8
OSPFv2 Area Ranges
Overview
You can create address ranges in the "Area Ranges" dialog that allow various address
ranges to be grouped when propagating. This allows the number of summary LSAs in the
areas to be reduced.
Figure 4-138 OSPFv2 Area Ranges
Area ID
Area ID to which the address range relates.
Subnet Address
Address of the network area to be grouped.

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals