Configuration using Web Based Management and Command Line Interface
4.4 The Agent menu
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
125
End date
Enter the following values for the end of daylight saving time:
Week of the month
You can select the 1st to 5th or the last week of the month.
Weekday
Month
Time of day in hours
Settings with "Date Entry Configuration" selected
You can set a fixed date for the start and end of daylight saving time.
Year
Enter the year for the daylight saving time changeover.
Start date
Enter the following values for the start of daylight saving time:
Month
Day
Time of day in hours
End date
Enter the following values for the end of daylight saving time:
Month
Day
Time of day in hours
Syntax of the Command Line Interface
Table 4- 34 Daylight Saving Time Table - CLI\AGENT\TIME\DST>
Command
Description
Comment
info Shows information about the time zone and
the daylight saving time changeover.
recurring <start
date> <end date>
Creates an entry of the type "Recurring".
You need to enter the following information for
the <start date > and <end date >:
1-5 or Last
Weekday
Month
Hour
Administrator only
Example:
recurring last sunday march 02
last sunday october 03

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals