Configuration using Web Based Management and Command Line Interface
4.5 The Switch menu
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
165
Syntax of the Command Line Interface
Table 4- 45 Access Control List Learning - CLI\SWITCH\UCAST>
Command
Description
Comment
learning [start|stop] No parameter
Displays the current status of the automatic learning.
start
Starts automatic learning.
stop
Stops automatic learning.
Administrator only.
clear Deletes all static unicast entries. Administrator only.