Configuration using Web Based Management and Command Line Interface
4.5 The Switch menu
SCALANCE X-300 / X-400
268 Configuration Manual, 10/2014, C79000-G8976-C187-22
Max. Utilization
Displays the peak value of port utilization as a percentage (%).
Note
With X300, the Utilization value is calculated
from the incoming frames. Only correct frames
are relevant.
With X414, the Utilization value is calculated from the incoming and outgoing frames. With
the incoming frames, both correct and bad frames are relevant. With the outgoing frames,
only correct fra
mes are relevant.
Syntax of the Command Line Interface
Table 4- 84 Statistics Throughput - CLI\SWITCH\STATS>
Command
Description
Comment
info Shows statistical information on sent and received
frames.
Administrator only.
size [ports] Displays information on the length of the sent and
received frames.
Administrator only.
type [ports] Displays information on the type of the sent and re-
ceived frames.
Administrator only.
error [ports]
Displays information on bad sent and received frames.
Administrator only.
clear
Resets the counters.
Administrator only.